This report was generated on Wednesday, 23-Feb-22 22:48:15 CET using arduino-testlib.
Version: 1.1
More details
Board | Claims compatibility | Inclusion | ReadSignalQuality |
SendDataIOT2020ToDashboard |
---|---|---|---|---|
arduino:avr:uno
1.8.4 |
Yes ⚠️ | FAIL | FAIL | FAIL |
arduino:mbed_nano:nanorp2040connect
2.7.2 |
Yes ⚠️ | FAIL | FAIL | PASS |
arduino:megaavr:nona4809
1.8.7 |
Yes ⚠️ | FAIL | FAIL | PASS |
arduino:samd:mkrwifi1010
1.8.12 |
Yes ⚠️ | FAIL | FAIL | PASS |
esp32:esp32:d1_mini32
1.0.6 |
Yes ⚠️ | FAIL | FAIL | PASS |
Result: FAIL
/tmp/arduino-testlib2208572144/test/test.ino:1:10: fatal error: IoTtweetSIEMENS_SIMATIC.h.h: No such file or directory #include <IoTtweetSIEMENS_SIMATIC.h.h> ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~ compilation terminated.
Result: FAIL
/home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/examples/ReadSignalQuality/ReadSignalQuality.ino: In function 'void loop()': /home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/examples/ReadSignalQuality/ReadSignalQuality.ino:30:40: error: 'class IoTtweetSIEMENS_SIMATIC' has no member named 'readSignalQuality' signal SignalQuality = mySIMATIC.readSignalQuality(); ^~~~~~~~~~~~~~~~~
Result: FAIL
/home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/src/AIS_NB_BC95_IOT2020.cpp: In member function 'void AIS_NB_BC95_IOT2020::setupDevice(String)': /home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/src/AIS_NB_BC95_IOT2020.cpp:33:3: error: 'Serial1' was not declared in this scope Serial1.begin(9600); ^~~~~~~ /home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/src/AIS_NB_BC95_IOT2020.cpp:33:3: note: suggested alternative: 'Serial' Serial1.begin(9600); ^~~~~~~ Serial
Result: FAIL
/tmp/arduino-testlib1355300595/test/test.ino:1:10: fatal error: IoTtweetSIEMENS_SIMATIC.h.h: No such file or directory #include <IoTtweetSIEMENS_SIMATIC.h.h> ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~ compilation terminated.
Result: FAIL
/home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/examples/ReadSignalQuality/ReadSignalQuality.ino: In function 'void loop()': /home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/examples/ReadSignalQuality/ReadSignalQuality.ino:30:40: error: 'class IoTtweetSIEMENS_SIMATIC' has no member named 'readSignalQuality' signal SignalQuality = mySIMATIC.readSignalQuality(); ^~~~~~~~~~~~~~~~~
Result: PASS
Sketch uses 88500 bytes (0%) of program storage space. Maximum is 16777216 bytes. Global variables use 43812 bytes (16%) of dynamic memory, leaving 226524 bytes for local variables. Maximum is 270336 bytes.
Result: FAIL
/tmp/arduino-testlib1355300595/test/test.ino:1:10: fatal error: IoTtweetSIEMENS_SIMATIC.h.h: No such file or directory #include <IoTtweetSIEMENS_SIMATIC.h.h> ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~ compilation terminated.
Result: FAIL
/home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/examples/ReadSignalQuality/ReadSignalQuality.ino: In function 'void loop()': /home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/examples/ReadSignalQuality/ReadSignalQuality.ino:30:40: error: 'class IoTtweetSIEMENS_SIMATIC' has no member named 'readSignalQuality' signal SignalQuality = mySIMATIC.readSignalQuality(); ^~~~~~~~~~~~~~~~~
Result: PASS
Sketch uses 16625 bytes (33%) of program storage space. Maximum is 49152 bytes. Global variables use 550 bytes (8%) of dynamic memory, leaving 5594 bytes for local variables. Maximum is 6144 bytes.
Result: FAIL
/tmp/arduino-testlib2208572144/test/test.ino:1:10: fatal error: IoTtweetSIEMENS_SIMATIC.h.h: No such file or directory #include <IoTtweetSIEMENS_SIMATIC.h.h> ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~ compilation terminated.
Result: FAIL
/home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/examples/ReadSignalQuality/ReadSignalQuality.ino: In function 'void loop()': /home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/examples/ReadSignalQuality/ReadSignalQuality.ino:30:40: error: 'class IoTtweetSIEMENS_SIMATIC' has no member named 'readSignalQuality' signal SignalQuality = mySIMATIC.readSignalQuality(); ^~~~~~~~~~~~~~~~~
Result: PASS
Sketch uses 38236 bytes (14%) of program storage space. Maximum is 262144 bytes. Global variables use 3744 bytes (11%) of dynamic memory, leaving 29024 bytes for local variables. Maximum is 32768 bytes.
Result: FAIL
/tmp/arduino-testlib1462639295/test/test.ino:1:39: fatal error: IoTtweetSIEMENS_SIMATIC.h.h: No such file or directory compilation terminated.
Result: FAIL
/home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/examples/ReadSignalQuality/ReadSignalQuality.ino: In function 'void loop()': /home/ec2-user/arduino-testlib/cli-datadir/user/libraries/IoTtweetSIEMENS_SIMATIC/examples/ReadSignalQuality/ReadSignalQuality.ino:30:40: error: 'class IoTtweetSIEMENS_SIMATIC' has no member named 'readSignalQuality' signal SignalQuality = mySIMATIC.readSignalQuality(); ^
Result: PASS
Sketch uses 219222 bytes (16%) of program storage space. Maximum is 1310720 bytes. Global variables use 13792 bytes (4%) of dynamic memory, leaving 313888 bytes for local variables. Maximum is 327680 bytes.